                Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
                 
                 
                 
                 
                 
                Glass Tube Flowmeter
                LZB/LZJ series glass rot...
                Glass Tube Flowmeter
                Glass Tube Flowmeter
                LZB-()W/WB series micro ...
                Glass Tube Flowmeter

                 


                Electric contact bimetallic thermometer
                Product Model:WSSX
                Main technical parameters

                (1)Electric contact type: Upper and lower limit contact 、 single upper limit contact 、 double upper limit contact.
                (2)Accuracy class:
                a.Upper and lower limit electric contact 、single upper limit electric contact:class1.5 ;
                b.Double upper limit electric contact:the first upper limit is class 1.5;the second upper limit is class 4;
                c.The setted error of contact is 1.5 times of the indicating value basic error.
                (3)Rated power on contact 10W:
                a.The maximum working voltage on the contact is 220V AC and maximum working current on the contact is 1A(non inductive
                load );
                b. Working voltage recommended is lower than 36V , but shouldn't be less than 12 V to guarantee that the contact moves reliablly.
                (4)Dial plate nominal diameter:100mm 、60mm.

                (5) Time constant, nominal pressure, jacket material are as same as WSS thermometer.
                ◆ The profile and electric diagram
                ◇ The profile and electric diagram of WSSX-301 electric contact bimetallic thermometer

                (mm)

                Model

                Measuring
                range℃

                Value of
                division℃

                Insert length

                Jacket diameter

                Installation
                thread

                Electric
                contact type

                Dial plate
                nominal diameter

                WSSX-301
                WSSX-302

                -80~+40*

                2

                75
                100
                150
                200
                250
                300

                6

                M16×1.5

                Single upper
                limit terminal

                60

                -40~+80*

                0~100

                0~150

                0~200

                5

                0~300

                Note:The measuring range with * doesn't include insert length of 75mm.

                 

                WSSX- 401 411/402 412 electric contact bimetallic thermometer

                (mm)

                                                           Table7                                               (mm)

                Model

                 

                Measuring
                range℃

                Value of
                division℃

                Insert length

                Jacket diameter

                Installation
                thread

                Dial plate
                nominal diameter

                WSSX-401
                WSSX-402
                WSSX-411
                WSSX-412

                -80~+40*

                2

                75
                100
                150
                200
                250
                300
                400
                500
                750
                1000

                10

                M27×2

                100

                -40~+80*

                0~100

                0~150

                0~200

                5

                0~300

                1250
                1500
                1750
                2000

                12

                0~400

                10

                0~500*

                Note: For the measuring range with ..,when the insert length is 75mm ,that shall be negotiated separately